MALCOM TOTAL MONITORING SYSTEM FOR REFLOW PROCESS CONTROL (TMR)
Malcom has developed a set of tools for the monitoring of your reflow process control.


MALCOM RCA-1 OBSERVATION MONITOR
Observe and record video of your PCB as it passes through the reflow oven.

SPECIFICATIONS:
| Item | Specifications |
| Camera | 1/4 inch Color CCD 400 thousand pixels |
| Field Size * Lens replacement system |
5(W)×4(H)mm W.D 5mm~61(W)×46(H)mm When W.D is 200mm, LED is the current lighting range. |
| Measurement Range (Temp.) | 0~300℃ |
| Measurement Accuracy (Temp.) | ±2℃ |
| Outer Dimension | 300W×52D×26H(mm) |

MALCOM RC0-1 OXYGEN MONITOR
Measure the oxygen concentration as the monitor passes through the reflow oven.

SPECIFICATIONS:
| Item | Specifications |
| Measurement Principle (O2 Concentration) |
Zirconia method |
| Measurement Range (O2 Concentration) |
50ppm~5000ppm |
| Measurement Accuracy (O2 Concentration) |
50ppm~1000ppm±5%FS 1000ppm~5000ppm±10%FS |
| Measurement Range (Temp.) | 0~300℃ |
| Measurement Accuracy (Temp.) | ±2℃ |
| Outer Dimension | 270W×52D×26H(mm) |

MALCOM RCW-1 VELOCITY MONITOR
Measure the blower fan air velocity as the monitor passes through the reflow oven.


SPECIFICATIONS:
| Item | Specifications |
| Measurement Range (Air Velocity) | 0.1~5m/s |
| Measurement Accuracy (Air Velocity) |
±(5%+0.1m/s)of the indicated value |
| Measurement Range (Temp.) | 0~300℃ |
| Measurement Accuracy (Temp.) | ±2℃ |
| Outer Dimension | 270W×52D×24H(mm) |


MALCOM TMR PREDICTION SOFTWARE
Software to be used in conduction with the TMR Monitoring System.